United Kingdom (English) Change Country
You are here: Home > Marine > Products > Propulsors > Propellers > Controllable pitch propellers > Oil distribution systems
The distribution box, available in five sizes incorporates the pitch feedback system and is mounted on the forward end of the reduction gearbox.
Installation space is minimised and the reduction gearbox can be removed without docking the ship.


| T.O-Box/ O.D-Box | A | B | C | D | E | F | Weight |
|---|---|---|---|---|---|---|---|
| 35 | 355 | 121 | 78 | 240 | 210 | 233 | 50 |
| 50 | 481 | 116 | 77 | 294 | 274 | 263 | 90 |
| 70 | 651 | 170 | 105 | 400 | 380 | 314 | 205 |
| 100 | 860 | 221 | 130 | 510 | 470 | 364 | 330 |
| 140 | 1079 | 270 | 175 | 625 | 620 | 439 | 640 |
Table / pictures (Dimensions in mm) B=Minimum distance for OD box dismantling
The forward part of the distribution box shaft incorporates the pitch feedback mechanism and has an integral flange connecting to the engine, reduction gearbox or solid intermediate shaft flange. Available in eight sizes.


| Size | D | D1 | D2 | L | L |
|---|---|---|---|---|---|
| Max | Min* | Min** | |||
| 230 | 230 | 395 | 450 | 1350 | 1900 |
| 300 | 300 | 185 | 550 | 1620 | 2200 |
| 380 | 380 | 595 | 685 | 1910 | 2700 |
| 450 | 450 | 695 | 795 | 2140 | 3000 |
| 550 | 550 | 830 | 950 | 2400 | 3500 |
| 620 | 620 | 930 | 1100 | 3000 | 4200 |
| 700 | 700 | 1080 | 1240 | 3200 | 4700 |
| 900 | 900 | 1370 | 1560 | 4000 | 5800 |
Table / pictures (Dimensions in mm)
* Coupling placed on propeller shaft at installation
**Coupling placed on OD box shaft at installation
The distribution box is integrated in the reduction gear, part of an integrated propulsion system. It is designed as a combined speed reduction unit with common hydraulics for gear and propeller.

The compact powerpack that comes in five sizes has its own integral oil tank and is equipped with two electric motors driving load sensing pitch setting pumps and all necessary valves, filters and coolers.
The second pump will automatically start if the oil pressure drops below a pre-set level to provide the required level of redundancy.

| HPP Size (ltr) | A | B | C | D | E | F | G | Min. Service Space mm | Weight without oil | Weight with oil |
|---|---|---|---|---|---|---|---|---|---|---|
| (mm) | (Kg) | |||||||||
| 150 | 1060 | 720 | 1360 | 980 | 825 | 650 | Æ22 | 1500 | 1000 | 1110 |
| 300 | 1120 | 930 | 1510 | 1060 | 1130 | 830 | Æ22 | 1750 | 1200 | 1420 |
| 500 | 1360 | 1090 | 1620 | 1240 | 1220 | 990 | Æ22 | 1800 | 1350 | 1700 |
| 700 | 1360 | 1090 | 1780 | 1240 | 1420 | 990 | Æ22 | 1950 | 1450 | 1950 |
| 1000 | - | - | - | - | - | - | Æ- | - | - | - |
Dimensions in the table are not binding.
Right of alterations reserved.